FIRE ENGINEERING FIRE APPARATUS FIRE FIGHTER NATION FE Books & Videos EMSToday JEMS

ANP Technologies, Inc.

Newark,  DE 
United States
http://www.anptinc.com
  • Booth: 9518


A Leader in Nanotherapeutics, Immunogenicity and Biodefense

ANP produces tools for the U.S. Military, first responders, and emergency health professionals to detect biological warfare agents in white powder. Our rapid assay and handheld assay can detect up to 5 targets at a time in a single ticket, and are immune to the high-dose Hook effect, a highly dangerous false negative result with high concentrations.

Brands: biological warfare, white powder, rapid detection, bio threat, biological warfare agents, handheld assay, multiplexed assay, high concentration, hook effect


 Products

  • NIDS® 3000 Biothreat Detection System
    The NIDS® handheld reader is a palm-sized, portable, scanning device that reads Bio threat Handheld Assay results in field conditions while wearing PPE....

  • Nano–Intelligent Detection System (NIDS®) BioThreat Rapid Assay and Handheld Reader. This platform utilizes Lateral Flow Immunochromatography (LFI) in which capture antibodies are immobilized onto the substrate surface. Liquid sample is introduced onto the card and a wicking process forces a diffusion of the liquid analyte along a path toward interaction between the capture antibody and the analyte. A colorimetric change takes place if the analyte is present. ANP markets a multianalyte LFI strip for screening against several pathogens/toxins assembled in a microarray format. LFI strips are analyzed by inserting into a reader that is colorimetric based. Single target assays and multiplexes in 2-plex, 3-plex, 4-plex, and 5-plex formats are available.

    • Confirms the identity up to 10 bio agents & simulants in under 15 minutes

    • Identifies up to 5 agents per test strip with only 100 uL of sample fluid

    • Eliminates false negatives due to the Hook Effect

    • Assays have 2 year shelf life over a wide temperature range

    • Easy-to-use reader even while wearing PPE

    • Stores up to 3,000 test results, including a preserved scanned image of each test, on a microSD disc

  • Biothreat Handheld Assays
    The NIDS-3000 is the ideal HandHeld sensor to rapidly screen powder, liquid or surfaces with no need for serial dilutions. Also, it does not suffer from the Hook Effect, a deadly false negative result in the presence of highly concentrated samples....

  • Nano–Intelligent Detection System (NIDS®) BioThreat Rapid Assay and Handheld Reader. This platform utilizes Lateral Flow Immunochromatography (LFI) in which capture antibodies are immobilized onto the substrate surface. Liquid sample is introduced onto the card and a wicking process forces a diffusion of the liquid analyte along a path toward interaction between the capture antibody and the analyte. A colorimetric change takes place if the analyte is present. ANP markets a multianalyte LFI strip for screening against several pathogens/toxins assembled in a microarray format. LFI strips are analyzed by inserting into a reader that is colorimetric based. Single target assays and multiplexes in 2-plex, 3-plex, 4-plex, and 5-plex formats are available.

    Single target assays and multiplexes in 2-plex, 5-plex, and 10-plex formats for the detection of:

    • B. anthracis

    • Vaccinia

    • Brucella

    • Venezuelan Equine Encephalitis

    • Listeria

    • SEB

    • F. tularensis

    • Botulinum Toxin A

    • V. cholerae

    • E. coli 0157

    • Ricin

    • Coxiella burnetii

    • Y. pestis

    • Salmonella


Send Email

Type your information and click "Send Email" to send an email to this exhibitor. To return to the previous screen without saving, click "Reset".


For Technical Support with this webpage, please contact support.