CHARACTERISTICS
Signaling Pin: after actuation the pin remains activated and should return to the original position manually. In valves equipped with contacts, the pin activates the contacts that are connected in the protection system and turning off of the transformer.
Protection against hot oil: the valves are equipped with a protection metallic cover, directing the oil to the sides. In relief valves with flow director (VAD) a piping is required for oil capture.
DEVICES
PRESSURE RELIEF VA 46 / 2 WITH ELECTRIC CONTACTS
FEATURES Operating pressure calibrated in 0,7 kgF/cm² or according to customer specification. Signaling pin in yellow. Reservoir capacity: 6.000 l
CONTACT Electric diagram: 2NO + 2NC Capacities: 0,6 A – 110 Vcc 0,4 A – 220 Vcc 4 A – 220 Vcc -
MATERIAL body in aluminum, hardware in stainless steel, nitrile rubber gaskets, painting Munsell N 6.5 light grey, N-1195
Protected against water and dust penetration as per IP 65 NBR 6146, in compliance with NBR 12 457 Rule
PRESSURE RELIEF VA 46 S/C
FEATURES: Operating pressure calibrated in 0,7 kgF/cm² or according to customer specification. Signaling pin in yellow. Reservoir capacity: 6.000 l
MATERIAL body in aluminum, hardware in stainless steel, nitrile rubber gaskets, painting Munsell N 6.5 light grey, N-1195
Protected against water and dust penetration as per IP 65 NBR 6146, in compliance with NBR 12 457 Rule
PRESSURE RELIEF VA 80 / 2 WITH ELECTRIC CONTACTS
FEATURES Operating pressure calibrated in 0,7 kgF/cm² or according to customer specification. Signaling pin in yellow. Reservoir capacity: 15.000 l
CONTACT Electric diagram: 2NO + 2NC Capacities: 0,6 A – 110 Vcc 0,4 A – 220 Vcc 4 A – 220 Vcc -
MATERIAL body in aluminum, hardware in stainless steel, nitrile rubber gaskets, painting Munsell N 6.5 light grey, N-1195
Protected against water and dust penetration as per IP 65 NBR 6146, in compliance with NBR 12 457 Rule
PRESSURE RELIEF VAD 80 / 2 WITH ELECTRIC CONTACTS
FEATURES Operating pressure calibrated in 0,7 kgF/cm² or according to customer specification. Signaling pin in yellow. Reservoir capacity: 15.000 l
CONTACT Electric diagram: 2NO + 2NC Capacities: 0,6 A – 110 Vcc 0,4 A – 220 Vcc 4 A – 220 Vcc -
MATERIAL body in aluminum, hardware in stainless steel, nitrile rubber gaskets, painting Munsell N 6.5 light grey, N-1195
Protected against water and dust penetration as per IP 65 NBR 6146, in compliance with NBR 12 457 Rule
PRESSURE RELIEF VA 125 / 2 WITH ELECTRIC CONTACTS
FEATURES Operating pressure calibrated in 0,7 kgF/cm² or according to customer specification. Signaling pin in yellow. Reservoir capacity: 38.000 l
CONTACT Electric diagram: 2NO + 2NC Capacities: 0,6 A – 110 Vcc 0,4 A – 220 Vcc 4 A – 220 Vcc -
MATERIAL body in aluminum, hardware in stainless steel, nitrile rubber gaskets, painting Munsell N 6.5 light grey, N-1195
Protected against water and dust penetration as per IP 65 NBR 6146, in compliance with NBR 12 457 Rule
PRESSURE RELIEF VAD 125 / 2 WITH ELECTRIC CONTACTS
FEATURES Operating pressure calibrated in 0,7 kgF/cm² or according to customer specification. Signaling pin in yellow. Reservoir capacity: 35.000 l
CONTACT Electric diagram: 2NO + 2NC Capacities: 0,6 A – 110 Vcc 0,4 A – 220 Vcc 4 A – 220 Vcc -
MATERIAL body in aluminum, hardware in stainless steel, nitrile rubber gaskets, painting Munsell N 6.5 light grey, N-1195
Protected against water and dust penetration as per IP 65 NBR 6146, in compliance with NBR 12 457 Rule
PRESSURE RELIEF VADF 125 / 2 WITH ELECTRIC CONTACTS
FEATURES Operating pressure calibrated in 0,7 kgF/cm² or according to customer specification. Signaling pin in yellow. Reservoir capacity: 35.000 l
CONTACT Electric diagram: 2NO + 2NC Capacities: 0,6 A – 110 Vcc 0,4 A – 220 Vcc 4 A – 220 Vcc -
MATERIAL body in aluminum, hardware in stainless steel, nitrile rubber gasket, painting Munsell N 6.5 light grey, N-1195
Protected against water and dust penetration as per IP 65 NBR 6146, in compliance with NBR 12 457 Rule