Modine/Coiltech

Grenada,  MS 
United States
http://www.modine.com
  • Booth: 1211

Modine CIS manufactures Coiltech Industrial Heat Transfer products. Coiltech products are used in industries such as renewable energy, power generation, power transmission & many other energy related heat removal/cooling applications. 


 Products

  • Steam Coil
    Coiltech steam coils are specifically designed with condensate management in mind. Tube and connection size are combined to limit condensate retention in the coil, preventing water hammer while delivering even distribution of steam on the entire face....

  • Coiltech steam coils are specifically designed with condensate management in mind. Tube and connection size are combined to limit condensate retention in the coil, preventing water hammer while delivering even distribution of steam on the entire face.

    With single-tube coils, the steam supply and condensate return headers and connections are normally at the opposite ends of the coil. Uniform steam distribution to each of the coil core tubes is accomplished through careful header-assembly design. The steam supply connection should be located in the centre of the header, with a perforated plate-type baffle located directly behind this connection. Carefully sized orifices are located in each of the core tube entrances into the header.

    Dual-tube coils utilise a smaller inner tube, with precisely spaced, directional, orifice-type perforations. This helps to direct condensate flow to the return header. The steam supply, condensate-return headers, and connections may be fabricated in 'same-end' or 'opposite-end' orientation.

    Steam Coil Application

    ·  Commercial and industrial heating systems

    ·  Commercial and industrial drying and processing applications

    Steam Coil Specifications

    Tube material

    ·  Copper

    ·  Copper nickel

    ·  Carbon steel

    ·  Stainless steel

    Additional tube material available upon request

    Fin material

    ·  Aluminum

    ·  Copper

    ·  Stainless steel

    ·  Carbon steel

    Additional fin material available upon request

    Standard or steam distributing construction is available for high and low pressure applications. Standard steam type is 5/8" or 1" tube steam coil, known as the single-tube design.

    Any steam coil can freeze when exposed to sub-zero temperatures without the proper drainage of the condensate. Steam-distributing 5/8" and 1" tubes are "freeze resistant", known as the dual-tube design.

  • Transformer Oil Cooler
    Transformer Oil Cooler Specifications...

  • Coil features

    High heat exchange efficiency

    Removable headers, manufactured from anticorrosion coated steel

    Rubber O-rings between the headers and the tube plates, for an effective seal

    High resistance to corrosion

    Good resistance against clogging

    Plugged vent and drain connections at each header

    Casing features

    Coil casing: hot dipped galvanized steel

    Fan deck and fan ring: aluminum

    Externally painted for color matching (on request)

    Fan motor features

    Three phase, with squirrel-cage

    Various speeds depending on acoustic requirements

    Axial fan geometry

    Direct drive

    Protection grade: IP 55

    Class of insulation: F

    Impeller dynamically balanced

    Impeller blades in aluminum

    Hub in anti-corrosion coated steel

    Fan guard features

    Easily removable

  • Generator Cooler
    One of Coiltech's specialist areas is in producing cleanable coolers for electric motors and generators which are used in sea or river water, or in offshore and nuclear power plants....

  • Our coolers are produced either with single or double tubes. The single tube version is suitable for almost any environment, whilst the double tube version has been designed for more critical applications, such as offshore platforms, marine installations or power stations.

    Preventing damage from leakage
    In the double tube version, any leakage from the inner tube enters the outer tube, where a leakage detector sets off an alarm. The outer tube then captures any leaked liquid, and prevents it from causing damage to the rest of the installation.