Kaixiang is a leading manufacturer of loadbanks in China. It specialize in design, development and manufacture all kinds of Resisitve Loadbank, Resistive/Inductive Loadbank, Portable Loadbank, Low/Medium/High Voltage Loadbank. Kaixiang , with more than 20 years' experience in testing Generators, Batteries and UPS, etc.

Brands: Loadbanks; Resistive loadbank; Inductive/reactive loadbank; AC loadbank; portable load bank; medium/high voltage load bank; variable load bank; load bank for generator; load bank testing; loadbanks


 Products

  • AC400-100kW Automatic Load Bank
    400VAC 3 phase 4 wire 50/60Hz, 100kW resistive load bank...

  • Foreword

    This specification introduces AC400-100kW Automatic Load Bank and its accessories, including their function, performance, usage, providing users with a high efficient and reliable choice to test generator or UPS.

    Items

    Quantity

    Remark

    AC400-100kW Automatic Load Bank

    1 sets

    Power Cord

    1

    3 meters 

    RS485

    1

    10 meters

    RS485/RS232/USB Converter

    1

    Documents accompanied with shipment

    Quantity

    Remark

    Operation Instruction

    2

    Certification

    1

    Warranty Card

    1

    12 months

    Packing List

    1

    Receiving Apron

    1

    Data Managing Software U-disk

    1

    Testing Report

    1

    Technical Parameter

    System Parameter

    Rating voltage/frequency

    400VAC power 100kW; 3 phase 4 wire, 50/60Hz

    Max Load Power

    100kW

    Load Resolution

    Resistive Load: 8 steps, 1, 2, 2, 5, 10, 10, 20, 50kW

    Power Factor

    1

    Load Tolerance  (each step)

    ±5%

    Load Tolerance (overall)

    ±3%

    Fan Control Power

    External power 220VAC single phase, 50Hz

    Wire Connection

    Load bank input——terminal block

    Control power input——3-pin plug

    Communication Interface

    RS232/ RS485

    Insulation

    F

    Way of Working

    Continuous Working

    Cooling

    Forced air cooling, horizontal inlet air and cooling

    Transportation

    Hoisting, also with wheel castors in bottom

    Color

    Gray 7035 or as customer’s request

    Dimensions

    About 700mm*700mm*1050mm (L×W×H) with lifting eyes and wheel castors

    Weight

    About 140kg

    Operating Environment Parameter

    Ambient Temperature

    -10°C~+50°C

    Relative Humidity

    ≤95%

    Atmospheric Pressure

    86~106kPa

    Brands of Main Components

    Contactor

    Schneider

    Fuse

    MIRO

    PLC

    SIEMENS

    Alloy Resistor

    (self-developing)

    Data Processing Software

     (self-developing)

    Multi-function Meter

    QINGZHI (Model 3432B)

    Functions

    • 3 line LED multi-function meter can display real-time voltage and current of three phase and each phase, resistive power, frequency and running time of generating set or UPS.
    • User can pre-set the power then press the master load button.
    • Control mode: user can choose local control or intelligent control (through PC)
    • Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.

    Protection

    • Have emergency stop button.
    • In case of over-load, over-heat, short circuit, load bank will automatically remove load and give alarm.
    • Fan protection: Load bank could not load before power of fan is on.
    • Give alarm when any fan is abnormal or with insufficient air volume, etc.
    • Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.

    Data Processing Software 

    • Automatic load: User can set several periods of power and duration and in turn of 0%→25%→50%→75%→100% or 110% then →75%→50%→25%→0%.etc to make automatic load testing.
    • Can make parallel testing for several units.
    • Data can be saved, could display real-time data and history data.
    • Charts and graphs can be exported in format of JPG while testing data exported in Excel and Word format, and all can be printed.
  • AC400-500kW Automatic Load Bank
    400VAC 3 phase 4 wire 50/60Hz, resistive power 500kW. powre factor 1....

  • Foreword

    This solution introduces AC400-500kW Automatic Load Bank and its accessories, including their function, performance, usage, structure, providing users with a high efficient and reliable choice to test generator.

    All the pictures quoted in this agreement are for reference only.

    Supply List

    The following form presents the accessories provided when we make shipment.

    Items

    Quantity

    Remark

    AC400-500kW Automatic Load Bank

    1 sets

    Power Cord

    1

    3 meters 

    RS485

    1

    10 meters

    RS485/RS232/USB Converter

    1

    Documents accompanied with shipment

    Quantity

    Remark

    Operation Instruction

    2

    Certification

    1

    Warranty Card

    1

    12 months

    Packing List

    1

    Receiving Apron

    1

    Data Managing Software U-disk

    1

    Testing Report

    1

    Technical Parameter

    Technical Parameter

    Rating voltage/frequency

    400VAC power 500kW; 3 phase 4 wire, 50Hz, phase voltage 230VAC

    Max Load Power

    500kW

    Load Resolution

    Resistive Load: 11 steps, 1, 2, 2, 5, 10, 10, 20, 50, 100, 100, 200kW

    Power Factor

    1

    Load Tolerance  (each step)

    ±5%

    Load Tolerance (overall)

    ±3%

    Display Meter

    Multiple function meter

    Fan Control Power

    External power 380VAC 3 phase 4 wire 50Hz

    Wire Connection

    Load bank input——busbar (star coupling “Y”)

    Control power input——terminal block

    Communication Interface

    RS232/RS485

    Insulation

    F

    Way of Working

    Continuous Working

    Cooling

    Forced air, horizontal air intake and upwards exhaust cooling

    Transportation

    With lifting eyes and wheel castors

    Color

    As customer’s requirements or as our design

    Dimensions

    About 1550*1250*1680mm L×W×H, height do not include height of lifting eye (100mm) with wheel castor (200mm)

    Weight

    About 700kg

    Operating Environment Parameter

    Ambient Temperature

    -10℃~+50℃

    Relative Humidity

    ≤95%

    Atmospheric Pressure

    86~106kPa

    Using Place

    Indoor

    Brands of Main Components

    Contactor

    Schneider

    Fuse

    MIRO

    PLC

    Siemens

    Alloy Resistor

    (self-developing)

    Data Processing Software

     (self-developing)

    Functions

    • 3 line LED multi-function meter can display real-time voltage and current of three phase and each phase, resistive power, power factor, apparent power, frequency and running time of generating set.
    • User can pre-set the power then press the master load button.
    • Control mode: user can choose local control or intelligent control (through PC)
    • Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.

    Protection

    • Have emergency stop button.
    • In case of over-load, over-heat, short circuit, load bank will automatically remove load and give alarm.
    • Fan protection: Load bank could not load before power of fan is on.
    • Give alarm when any fan is abnormal or with insufficient air volume, etc.
    • Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.

    Data Processing Software 

    • Automatic load: User can set several periods of power and duration and in turn of 0%→25%→50%→75%→100% or 110% then →75%→50%→25%→0%.etc to make automatic load testing.
    • Can make parallel testing for several units.
    • Data can be saved, could display real-time data and history data.
    • Charts and graphs can be exported in format of JPG while testing data exported in Excel and Word format, and all can be printed.
  • AC400-2000kW Automatic Load Bank
    400VAC 3 phase 4 wire 50/60Hz, resistive 2000kW, power factor 1...

  • Foreword

    This agreement introduces AC400-2000kW Automatic Load Bank and its accessories, including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice for generator loading test.

     

    Supply List

    The following form presents the accessories provided when we make shipment.

    Items

    Quantity

    Remark

    AC400-2000kW Automatic Load Bank

    1 sets

    RS485

    1

    30 meters

    Remote Control Box

    1

    Portable

    RS485/RS232/USB Converter

    1

    Documents accompanied with shipment

    Quantity

    Remark

    Operation Instruction

    2

    Certification

    1

    Warranty Card

    1

    12 months

    Packing List

    1

    Receiving Apron

    1

    Data Managing Software U-disk

    1

    Testing Report

    1

    4 Technical Parameter

    Technical Parameter

    Rating voltage/frequency

    400VAC 2000kW, 3 phase 4 wire, 50Hz

    Max Load Power

    When 400V: 2000kW

    Load Resolution

    When 400V: 1, 2, 2, 5, 10, 10, 20, 50, 100, 200kW*9 minimum step 1kW

    Power Factor

    1

    Load Tolerance  (resistive)

    ±5%

    Load Tolerance (inductive)

    ±3%

    Display Meter

    Multiple function meter

    Fan Control Power

    External 380VAC 3 phase 4 wire, 50Hz

    Wire Connection

    Load bank input——Copper bar (star coupling ”Y”)

    Control power input——terminal block

    Communication Interface

    RS232/RS485

    Insulation

    F

    Way of Working

    Continuous Working

    Cooling

    Forced air cooling, horizontal air intake and upwards exhaust cooling

    Transportation

    Hoisting, it has lifting eyes

    Color

    As customer’s requirements or as our design Gray 7035

    Dimensions

    About 6058*2350*2591mm (L*W*H)

    Weight

    About 5800kg

    Operating Environment Parameter

    Ambient Temperature

    -10℃~+50℃

    Relative Humidity

    ≤95%

    Atmospheric Pressure

    86~106kPa

    Brands of Main Components

    Contactor

    Schneider

    Fuse

    MIRO

    PLC

    Siemens

    Alloy Resistor

    (self-developing)

    Data Processing Software

     (self-developing)

    Functions

    User could load any power within rated power, can test voltage and current of three phase and each phase, resistive power, power factor, apparent power, frequency and running time of generating set.

    Whether load/unload by local control panel or by PC software control, user can pre-set the power then press the master load button.

    Control mode: user can choose local control or intelligent control (PC control)

    Local manual control: there is local control panel in load bank, with multi load steps, min load steps 1kW/0.3kW, controlled by buttons.

    Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph and can be printed.

    Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.

    With data processing software, could form curves of current, voltage, resistive power, apparent power, and frequency, can be printed.

    One-key load/unload: user can load or unload with one key easy to control.

    3 line LED multi-function meter display.

    Data Processing Software Functions

    Communication type: through RS232, RS485 or USB interface.

    Load mode: manual load or automatic load.

    Manual load: input power and power factor.

    Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100% or 110%, etc to make automatic load testing.

    Parallel testing: when several load banks parallel working, parameters of each load bank can be displayed and recorded, so do the final parameters of paralleling working.

    Real-time parameter: Current, voltage, power, power factor, frequency, time, etc could be displayed by software.

    Safety monitoring: User can know the working conditions of load bank through software indicating light. When in abnormal stop protection, software will indicate the reasons of stopping.

    Data collection interval: the min saving interval is 2 seconds.

    Data saving and in query: testing data could be saved in software, user can query at any time.

     Data display: it could display real-time data and history data; user can print voltage, current, frequency, power graphs and charts.

     Charts and graphs are output in format of JPG while testing data output in Excel format, and all can be printed.