Burners, Igniters, Dampers, Controls - Flame Detectors

90 years of providing customized combustion solutions
Burners - utility, duct burners, SCR Reheats
Igniters & warm up guns- oil or gas
Flame detectors - UV, IR or dual spectrum
Turbine igniters & flame detectors
Dampers - custom engineered louver, double louver, guillotine, poppet, HRSG diverter & stack dampers
Expansion joints
Air heater seals

Brands: MaxFire Gas Igniter, DuraFire Oil Igniter, advantage Duct Burner, BiPlane Louver Damper, combustion controls,


  • HD Flame Detector
    First industrial Flame Detector with an easy to use interface on a mobile app. The HD Flame Detector was designed for the Power Generation market and provides the highest level of flame discrimination in multi-burner applications ....

  • Product Overview

    The Forney High Definition (HD) Flame Detector integrates both Infrared (IR) and Ultraviolet (UV) optical sensors along with an amplifier and high speed signal processor. The high speed signal processor is able to analyze frequency resolution
    allowing for precise discrimination between multiple burners and background radiation. Two flame relays are available which can be triggered by either optical sensor. Four different profiles are selectable for maximum flexibility under different operating conditions. 4 to 20mA analog outputs are provided for remote display options.

    An industry first mobile app is available in two configurations from the Apple Store and Google Play. The Forney HD Detector app will allow the user to select a specific detector via Bluetooth. The user can then monitor the detector on their mobile device. A live Fast Fourier Transform (FFT) is also displayed. To tune the detector, the password protected, Forney HD Detector Pro app will allow the user to specify pick up and drop outs for flame on and flame off within the user specified frequency range or power spectrum density. They can also specify which sensor will be used for each flame relay and profile. Any fault codes are clearly shown with Reset capability. A PC based RS485 connection capability is also available.

    A single, flexible 12 wire custom cable is available in multiple lengths to make field connects simple. In many cases the existing field cabling can be reused. (Existing cables for Forney D85, UniFlame, and UniFlame II Detectors can be reused with transition adapters.)

    • High Definition – Maximum discrimination in difficult multiburner environments.
    • Easy to use – app available for either smart phones or tablets
    • Installation friendly – lightweight housing and single flexible cable
    • Robust – 2 year warranty in normal operating conditions

    • Both Infrared (IR) and Ultraviolet (UV) sensors in every unit
    • High speed microprocessor based signal analysis
    • Bluetooth® and RS485 Modbus communications
    • Simple LED status indicators on HD Detector unit for Power, Flame Relay 1 & 2, Fault, Bluetooth®, and High Temperature
    • IP 66 housing and connections
    • RoHS compliant

    Worldwide Agency Approvals
    • FM, CE, IECEX, Class I Div 2, Groups B,C &D, ATEX, Safety Integrity Level 3 (coming in 2017)


    Ambient Operating Temperature                             -30°C to 65° C (-22° F to 149° F)
    Ambient Storage and Transportation Temperature   20°C to 50°C (68°F to 122° F)

    Relative Humidity                                                    40°C (104°F), RH 95%
    Vibration Sinusoidal Operating Frequency:             5 -200 Hz Acceleration: 8G
    Flammability Rating                                                UL94 Conformal Coatings
    RoHS Compliant


    Housing Material                       Engineered Polymer
    Weight                                        1.18 Kg (2.6 lbs)
    Degree of Protection                  IP66 , NEMA 4X
    Sight Tube Mounting                 1” NPT
    Lens Temperature                      Rating 538°C (1000° F)
    Purge Air Flow                          Minimum 5 SCFM
    Optical Sensitivity                     Responsive to oil, coal & gas flames using IR & UV spectrum
    Power Supply                            24 VDC ( +10 /- 15%)
    Steady State Current                 120 ma
    Inrush Current                           350 ma
    Power Consumption                  2.88 watt
    External In-line Fuse                 1 Amp Fuse Required
    Heat Dissipation                        1.2 Watt
    Flame Relay                              Two (2) independent (fail safe)
    Contacts                                    SPST
                                                      24 VDC, 1 amp
    Flame Failure Response Time (FFRT) 1, 2, 3, 4 second (user adjustable)
    Fault Relay                               Internally Wired
    Analog Output                          Sourced 4-20 ma, one for each flame relay
                                                      Load resistance < 750 Ohm
    Digital Inputs                           Two self-powered inputs for up to four file selections
    Communication Port                RS-485 / Modbus Bluetooth®
    Electrical connections              Standard - Quick disconnect ATEX version - Prewired
    Prefabricated Cable                  12 Conductor (color coded)
                                                     Tinned Copper Braid Shield,
                                                     Black PVC Jacket CSA CMG (UL) PLTC-ER 300V 105C,
                                                     Fire Resistant - FT4, UV Resistance
                                                     Diameter -0.463” Nominal
                                                     Weight - 0.17 lb/ft