DATAKOM ELEKTRONIK MUHENDISLIK SAN VE TIC AS

ISTANBUL,  UMRANIYE 
Turkey
http://www.datakom.com.tr
  • Booth: 8824


GENSET PRODUCTS - ENERGY QUALITY - REMOTE MONITORING

Datakom is an electronics design and production company deeply involved in genset controls since 1994.Offers hightech,web based,cost effective genset controllers. The company is also involved in energy quality and remote monitoring/control systems. Products have multi-communication ports (GPRS,ethernet,etc). Many products UL certified.

Brands: Generator,synchronization,amf,genset,controller,metering,energy quality,ammeter,voltmeter,network analyzer,ats,paralleling,load sharing,check synchroscope,avr,governor,smps,battery charger,compressor


 Products

  • D-700 Advanced Genset Synchronization Controller
    Auto Learning Synchronization Controller
    (Black&White and Color Screen Versions)
    Tailored for the most demanding applications


    ...

  • Features

    • 4.3” 480x272 pixels color LCD

    • Diesel and gas genset support

    • Supports up to 48 gensets

    • Automatic learning/self adjust

    • Direct governor & AVR control

    • Voltage and phase matching

    • kW & kVAr load sharing

    • Multiple topologies

    • 6xCT, true mains metering

    • True soft transfer in both ways

    • Peak Lopping / peak shaving (mains or genset priority)

    • Mains de-coupling protection

    • R.O.C.O.F protection

    • Vector shift protection

    • Reverse power protection

    • Over/under freq. Protection

    • Over/under voltage protection

    • Smart load management

    • Smart genset sequencing

    • Run/stop priority support

    • Equal aging of gensets

    • Base load (power export)

    • Unmanaged distributed power export support

    • AVR & GOV droop support

    • Dead bus sensing

    • 400Hz operation support

    • 400 event logs, full snapshot

    • All parameters front panel editable

    • 3 level configuration password

    • 128x64 graphical LCD display

    • Downloadable languages

    • Waveform display of V & I

    • Harmonic analysis of V & I

    • Synchroscope & check synch

    • 12 configurable digital inputs

    • Inputs expandable to 44

    • 8 configurable digital outputs

    • Outputs expandable to 40

    • 7 configurable analog inputs

    • Both CANBUS-J1939 & MPU

    • 3 configurable service alarms

    • Multiple automatic exerciser

    • Weekly operation schedule

    • Dual mutual standby with equal aging of gensets

    • Manual “speed fine adjust” on selected ECUs

    • Automatic fuel pump control

    • Disable protections feature

    • Excess power protection

    • Overload IDMT protection

    • Load shedding, dummy load

    • Multiple load management

    • Current unbalance protection

    • Voltage unbalance protection

    • Fuel filling & fuel theft alarms

    • Battery back-up real time clock

    • Idle speed control

    • Battery charge run enabled

    • Combat mode support

    • Multiple nominal conditions

    • Contactor & MCB drive

    • 4 quadrant genset power counters

    • Mains power counters

    • Fuel filling counter

    • Fuel consumption counter

    • Modem & ethernet diagnostics

    • Configurable through USB, RS-485, Ethernet and GPRS

    • Free configuration program

    • Allows SMS controls

    • Ready for central monitoring ethernet & GPRS

    • Mobile genset support

    • Automatic GSM geo-location

    • GPS connectivity (USB&RS232)

    • Dynamic DNS support

    • Easy USB firmware upgrade

    • IP65 rating with standard gasket Communication

    • Ethernet (10/100Mb)

    • 4-band GPRS modem (optional)

    • USB Host & USB Device

    • RS-485 (2400-115200baud)

    • RS-232 (2400-115200baud)

    • Micro SD card slot

    • J1939-CANBUS

    • Geo-locating through GSM

    • GPS support (USB & RS-232)

    • Embedded web server

    • Web monitoring & programming

    • Internet Central Monitoring

    • SMS message sending

    • E-mail sending

    • Free PC software: Rainbow Plus

    • Modbus RTU & Modbus TCP/IP

    • SNMP (with TRAP messages)

    • SNTP Functionalities

    • Multi genset synch & load share

    • Mains synchronization

    • Single genset parallel with mains

    • AMF unit (uninterrupted transfer)

    • ATS unit (uninterrupted transfer)

    • Remote start controller

    • Manual start controller

    • Engine controller

    • Remote display panel

    • Long term data record on flash

    • On-board Input&output extension

    Measurements

    • Mains & genset PN/PP voltages

    • Mains & genset frequency

    • Mains & genset phase currents

    • Mains & genset neutral currents

    • Mains & genset, phase & total,kW, kVA, kVAr, pf

    • Engine speed

    • Battery voltage

    Communication

    • Ethernet (10/100Mb)

    • 4-band GPRS modem (optional)

    • USB Host & USB Device

    • RS-485 (2400-115200baud)

    • RS-232 (2400-115200baud)

    • Micro SD card slot

    • J1939-CANBUS

    • Geo-locating through GSM

    • GPS support (USB & RS-232)

    • Embedded web server

    • Web monitoring & programming

    • Internet Central Monitoring

    • SMS message sending

    • E-mail sending

    • Free PC software: Rainbow Plus

    • Modbus RTU & Modbus TCP/IP

    • SNMP (with TRAP messages)

    • SNTP

    Functionalities

    • Multi genset synch & load share

    • Mains synchronization

    • Single genset parallel with mains

    • AMF unit (uninterrupted transfer)

    • ATS unit (uninterrupted transfer)

    • Remote start controller

    • Manual start controller

    • Engine controller

    • Remote display panel

    • Long term data record on flash

    • On-board Input&output extension

    Technical Specifications

    Alternator voltage: 0 to 300 V-AC (Ph-N)

    Alternator frequency: 0-600 Hz.

    Mains (Busbar) voltage: 0 to 300 V-AC (Ph-N)

    Mains (Busbar) frequency: 0-600 Hz.

    Topology: 1-2-3 phases, with or without neutral

    DC Supply Range: 8.0 to 36.0 V-DC.

    V-A-cos Accuracy: 0.5% + 1 digit

    kW-kVA-kVAr Accuracy: 1.0% + 1 digit

    Current consumption: 500 mA-DC max.

    Current Inputs: from current transformers. ../5A.

    Digital inputs: input voltage 0 to 36 V-DC.

    Analog input range: 0-5000 ohms.

    DigitalOutputs: Protected mosfet semiconductor outputs, rated 1Amp@28V-DC

    Cranking dropouts: survives 0V for 100ms.

    Magnetic pickup voltage: 0.5 to 50Vpk.

    Magnetic pickup frequency: 0 to 20000 Hz.

    GOV Control Output: 0-10V-DC

    AVR Control Output: ±5V-DC, fully isolated

    Charge Alternator Excitation: 2W.

    Display Screen: B/W versions: 2.9”, 128x64 pixels TFT versions: 4.3”, 480x272 pixels

    Ethernet Port: 10/100 Mbits

    USB Device: USB 2.0 Full speed

    USB Host: USB 2.0 Full speed

    RS-485 Port: selectable baud rate

    RS-232 Port: selectable baud rate 

    Data Link Port: Fully Isolated CANBUS

    Operating temperature: -20°C to 70°C (-4 to +158 °F)

    Storage temperature: -40°C to 80°C (-40 to +176°F)

    Maximum humidity: 95% non-condensing.

    IP Protection: IP65 from front panel, IP30 from the rear.

    Dimensions: 243 x 183 x 47mm (WxHxD)

    Panel Cut-out Dimensions: 216 x 156 mm minimum.

    Weight: 700 g /1.55lb (approx.)

    Case Material: High Temperature, non-flammable ABS/PC

    Installation: Flat surface mounting on a Type 1 enclosure.

    Rear retaining plastic brackets

  • D 500 Advanced Genset Controller
    Web Based D-500
    The D-500 is a next generation genset control unit combining multi-functionality and wide communication possibilities together with a reliable and low cost design.
    ...

  • Features

    • Waveform display of V & I

    • Harmonic analysis of V & I

    • Synchroscope & check synch

    • Allows closed transfers

    • 16Amp MCB & GCB outputs

    • 8 configurable digital inputs

    • Inputs expandable to 40

    • 8 configurable digital outputs

    • Outputs expandable to 40

    • 4 configurable analog inputs

    • Both CANBUS-J1939 & MPU

    • 3 configurable service alarms

    • Multiple automatic exerciser

    • Weekly operation schedule

    • Dual mutual standby with equal aging of gensets

    • Manual “speed fine adjust” on selected ECUs

    • Automatic fuel pump control

    • Disable protections feature

    • Excess power protection

    • Reverse power protection

    • Overload IDMT protection

    • Load shedding, dummy load

    • Multiple load management

    • Current unbalance protection

    • Voltage unbalance protection

    • Fuel filling & fuel theft alarms

    • Battery back-up real time clock

    • Idle speed control

    • Battery charge run enabled

    • Combat mode support

    • Multiple nominal conditions

    • Contactor & MCB drive

    • 4 quadrant genset power counters

    • Mains power counters

    • Fuel filling counter

    • Fuel consumption counter

    • Modem & ethernet diagnostics

    • Configurable through USB,RS-485, Ethernet and GPRS

    • Free configuration program

    • Allows SMS controls

    • Ready for central monitoring ethernet & GPRS

    • Mobile genset support

    • Automatic GSM geo-location

    • GPS connectivity (USB&RS232)

    • Dynamic DNS support

    • Easy USB firmware upgrade

    • IP65 rating with standard gasket

    Measurements

    • Mains & genset PN/PP voltages

    • Mains & genset frequency

    • Mains & genset phase currents

    • Mains & genset neutral currents

    • Mains & genset, phase & total,kW, kVA, kVAr, pf

    • Engine speed

    • Battery voltage

    Communications

    • Ethernet (10/100Mb)

    • 4-band GPRS modem (optional)

    • USB Host & USB Device

    • RS-485 (2400-115200baud)

    • RS-232 (2400-115200baud)

    • Micro SD card slot

    • J1939-CANBUS

    • Geo-locating through GSM

    • GPS support (USB & RS-232)

    • Embedded web server

    • Web monitoring & programming

    • Internet Central Monitoring

    • SMS message sending

    • E-mail sending

    • Free PC software: Rainbow Plus

    • Modbus RTU & Modbus TCP/IP

    • SNMP (with TRAP messages)

    • SNTP FUNCTIONALITIES

    • AMF unit (uninterrupted transfer)

    • ATS unit (uninterrupted transfer)

    • Remote start controller • Manual start controller

    • Engine controller

    • Remote display panel

    • Harmonic analysis of V & I

    • Internal battery (optional)

    • Long term data record on flash

    • Input & output extension

    Topologies

    3 ph 4 w, star & delta

    • 3 ph 3 w, 2 CTs

    • 2 ph 3 w

    • 1 phase 2 wires

  • DKM 411 Power Analyser
    Colour TFT Screen
    IP Communications
    Harmonic Analysis
    Scopemeter
    Advanced precision metering device offering an 3.5” size, 320x240 pixel color TFT, together with unrivalled remote monitoring capabilities...

  • Features

    True RMS measurements, 0.2% accuracy

    3.5” TFT LCD, 320x240 pixels

    Harmonic distortion display (63 harmonics)

    Oscilloscope, waveform display Phasor diagram display

    Internal battery backed-up real time clock

    Max demand display

    User configurable display screen 2 configurable relay outputs

    Energy pulse output capability

    2 opto-isolated, configurable digital inputs

    Dual active-reactive power counters

    Both mains/generator energy metering

    Configurable user counters

    Voltage transformer ratio for MV applications

    Password protected front panel programming

    Reduced panel depth

    Sealed front panel (IP54)

    Measurements

    Phase to phase voltages: U12-U23-U31-Uavg

    Phase to neutral voltages: V1-V2-V3-Vavg

    Phase currents: I1-I2-I3-In-Iavg-Itot

    Active power: P1-P2-P3-∑P

    Reactive power: Q1-Q2-Q3-∑Q

    Apparent power: S1-S2-S3-∑S

    Power factor: cos1-cos2-cos3-∑cos

    Active power counters: Pc1-Pc2

    Reactive power counters: Qc1-Qc2

    User counters: USR1-USR2-USR3-USR4

    2...63 Harmonics of any voltage or current

    Phase to neutral voltages vector angles

    Phase to phase voltages vector angles

    Phasor vector diagram

    Communications

    Modbus

    RTU RS-485

    Modbus TCP/IP

    SNMP TCP/IP server

    TCP/IP client

    UDP

    SMTP

    Embedded web server

    Web monitoring

    Web programming

    GSM-SMSsending e-mailsending

    Central Monitoring through IP

    Free configuration & monitoring software

    Communication Ports

    Ethernet 10/100Mb

    RS-485 isolated (Modbus RTU)

    RS-232 for external GPRS modem

    USB Host for data recording on flash memory

    USB Device for PC connection

    Supported Topologies

    3 phases 4 wires, star

    3 phases 3 wires, 3 CTs

    3 phases 3 wires, 2 CTs (L1-L2)

    3 phases 3 wires, 2 CTs (L1-L3)

    3 phases 4 wires, delta

    2 phases 3 wires, L1-L2

    2 phases 3 wires, L1-L3

    1 phase 2 wires


Send Email