A leading cooling tower components manufacturer.

Our services comprise cooling tower components engineering, manufacturing for package units up to large field erected cooling towers. Optimized inlet louvers, cooling fills, nozzles, drift eliminators. We supply new projects as well as retrofits.

Brands: inlet, air, intake, turbine, cooling, tower, component, high, performance, quality, fill, drift, louver, nozzle


 Products

  • OF21MA
    Antifouling, high efficiency cooling film fill.
    Simple, fast mechanical assembling - no VOC (gluing), no fumes (heat welding).
    Proofed design and quality....

  • Brentwood's AccuPac Offset-Gluted Fill combines the low-fouling characteristics of vertical flow design with the enhanced water distribution of cross-fluted designs. OF21MA's design yields comparable thermal performance to CF1900 but with lower potential for fouling at a lower cost.

    - High thermal peformance.

    - Increased fouling resistance over cross-fluted designs.

    - Bondedge with dedicated bond points for added strength and durability.

    - Material exceeds Cooling Technology Institute (CTI) Standard 136.

    - Mechanically assembled.

    - Most versatile fill for use in varying water qualities while maintaining high performance.

    - Engineered to provide the performance of a cross-fluted product with the fouling resistance of vertical-fluted fills.

    - Ideal for existing vetical-fluted thermal upgrades.

  • CF80MAx drift eliminator
    Hifgh efficiency counter flow cellular drift eliminator....

  • Brentwood's AccuPac Counterflow Cellular Drift Eliminators are constructed of and alternating series of corrugated and wave PVC sheets, assembled to form closed cells. The closed cell structure yields the greatest surface are for droplet capture in a given volume. Brentwood's latest generation of cellular drift eliminators are specifically engineered for counterflow applications to maximize drift removal efficiency and minimize pressure drop.

    CF80MAx offering the best drift removal efficiency of any drift eliminator on the market today. CF80MAx features beveled drainage tips to reduce pressure drop by up to 25 %. With field-verified drit test results of 0.0005 % per CTI Standard 140, there is no need to use double layer of drift eliminators to achieve high drift removal efficiency.

    - Patented Mechanical Assembly technology yields glue-free packs.

    - Modules nest with adjoining modules, eliminating gaps between packs nd providing seamless drift removal.

    - Can be field-cut for tight fits without sacrificing structural integrity.

    - Able to span up to 1.83 m, requiring fewer supports to minimize air blockage.

    UV-protected material meets Cooling Technology Institute (CTI) Standard 136.