Arbiter Systems Inc

PASO ROBLES,  CA 
United States
http://www.arbiter.com
  • Booth: 1937


Precision GPS Timing and Power Measurement Solutions

Arbiter Systems, the utility industry leader for GPS timing products for over 2 decades, will be introducing our new series of "GNSS Synchronized Clocks”. The Models 1201B/C, 1205B/C and 1206B/C will be on display featuring our “EPS” technology (Enhanced Performance and Security). This series of clocks support NTP, SNMP, PTP and IEEE 1588 with “Power Profile”. Also included is your choice of internal “Holdover Oscillators”. Please visit our booth and see the next generation of “GNSS Synchronized” timing products, for those “System Critical” applications.

 

 


 Products

  • Model 928A Power System Multimeter™
    The Model 928A Power System Multimeter with Floating-Point DSP™ Digital Signal Analysis is an AC Power measurement instrument, providing outstanding performance and flexibility in a small, hand-held package....
     

  • Not only does the Model 928A measures basic data and power quantities, but it also measures power quality including harmonics, flicker, sags, surges and interruptions.  Incorporating a graphic LCD display, serial communications, real time clock and an unprecedented combination of features makes the Model 928A the ideal instrument for the power professional.

  • Model 933A Portable Power Sentinel™
    Arbiter Systems®, Inc., Model 933A Portable Power Sentinel™ is the most accurate and most affordable portable power quality meter in the industry....
     

  • The proprietary EnergyDSA™ Digital Signal Analysis algorithms allow the user to measure or record harmonics, flicker (per IEC 61000-4-15, PST and Instantaneous), K-factor, and interruptions.  The data logging capabilities allow the user to specify which data to log as well as when to log the data, continuously or when user specified thresholds are exceeded.  The high accuracy, portability and data logging capabilities make the Portable Power Sentinel™ the perfect field analyzer for the power quality engineer.
  • Model 1094B GPS Substation Clock
    Arbiter Systems®, Inc., Model 1094B GPS Substation Clock is a GPS timing source for substations which includes as standard the most common configuration options found in our other models....
     

  • The Model 1094B with 250 ns (typical < 100 ns) worst-case accuracy meets the most demanding substation requirements, including synchrophasors.  The Model 1094B has 4 LEDs to monitor operating status, a 2 x 20 character LCD setup/status display and a keyboard.  The Model 1094B also comes equipped with a front panel screwdriver-slot power switch and white LED backlight.

  • Model 1133A Power Sentinel™
    Take a bite out of power problems and lost revenue with the Model 1133A Power Sentinel™ multifunction measurement unit. Combining six functions into one compact unit, the Model 1133A offers unprecedented accuracy, flexibility, and features....
     

  • The Model 1133A brings laboratory performance to the substation, delivering unprecedented revenue accuracy of 0.025% under most conditions.  Compare this to traditional watt-hour meters which are limited to an accuracy of no better that 0.1% in the lab, with increasing errors as conditions depart the ideal.  The Model 1133A can measure harmonics and K-factor, flicker, interruptions, and log data by time interval, or record out-of-limit events with time of occurrence.  You can set limits on any quantity. 

    The Model 1133A measures system (absolute) phase angle, system frequency.  These measurements are made possible with the Model 1133A's internal GPS synchronization.

    A built-in GPS satellite receiver synchronizes your Model 1133A within 1µs of Coordinated Universal Time (UTC).  Other substation equipment, such as digital fault recorders, solid-state relays, remote terminal units, and programmable log controllers, may be synchronized with the standard IRIG-B unmodulated time code output.

  • Model 1201B/C GNSS Synchronized Clock
    Arbiter Systems®, Inc., Model 1201B/C GNSS Synchronized Clock is a multi-satellite system (GPS/GLONASS/Galileo*/BeiDou*) timing source for precision applications....

  • Arbiter Systems®, Inc., Model 1201B/C GNSS Synchronized Clock is a multi-satellite system (GPS/GLONASS/Galileo*/BeiDou*) timing source for precision applications.  Arbiter’s next generation substation clock provides enhanced performance and security (EPS) while supporting the standard outputs and popular options of our existing clocks.  EPS benefits include multi-system timing sources, standard holdover oscillator, multiple levels of security, secure communications, and anti-spoofing technology.  The Model 1201B/C is compatible with Arbiter’s earlier clock models, supporting the same legacy options and outputs, while easing the transition to a more secure device.

  • Model 1205B/C GNSS Synchronized Clock
    The Arbiter Systems®, Inc., Model 1205B/C GNSS Synchronized Clock is a multi-satellite system (GPS/GLONASS/Galileo*/BeiDou*) timing source for precision applications....
     

  • Arbiter's next-generation substation clock provides enhanced performance and security (EPS) along with the wide range of functions you have come to expect from the leader in timing for the power industry.  EPS benefits include multi-system timing sources, standard holdover oscillator, multiple levels of security, secure communications, and anti-spoofing technology.

    The Model 1205 is available in two versions, the Model 1205B and the Model 1205C.  The Model 1205B has eight status LEDs, an LCD status back-lit display, and a keyboard. The Model 1205C adds a large (20 mm or 0.8 in.) LED time display. Both versions have 32 receiver channels, capable of tracking GNSS satellite systems simultaneously, providing optimum performance.  This accuracy applies to the PTP network timing, the high drive programmable pulse (including IRIG-B) outputs and optional outputs.  The standard holdover oscillator maintains accuracy of 1 ms/day or optionally 10 µs/day when not tracking satellites.  In addition to enhanced performance, Arbiter Systems' new EPS technology includes GNSS anti-spoofing and secure password-protected and encrypted configuration interface providing robust, reliable synchronization to help comply with latest NERC-CIP requirements.

    The Model 1205B/C timing signals are available via the three Ethernet ports, the thirty-two pin terminal block and from the available option slot.  The three 10/100 Ethernet ports (copper standard, fiber optional) provide status, configuration as well as network timing supporting the NTP, SNTP, PTP (Power Profile supported), SNMP, ICMP, TCP, SSH, SSL, HTTP, HTTPS and DHCP protocols.  The thirty-two pin terminal block provides access to the Model 1205B/C standard inputs, outputs and legacy communication ports.  Two inputs, an event timer and a frequency monitor, are included along with six Programmable Pulse outputs, a modulated IRIG-B output, a FET output, relay contacts, two RS-232 ports and a RS-422/485 port (transmit only).  The event timer, 100 ns resolution, accepts an external 5 V CMOS/TTL signal while the frequency monitor accepts a single phase AC voltage input (50/60 Hz, 120 Vac).  The Programmable Pulse high drive outputs (5 Vdc, 125 mA) are user configurable to unmodulated IRIG-B (UTC, Local, C37.118.1) or pulse output (one pulse a second to one pulse a day).  The modulated IRIG-B outputs a 4 Vpp (20 ohms source impedance) signal and supports C37.118.1.  An SPDT (form C) fail-safe relay is also included and is configurable to Out-of-Lock, Fault, Alarm, Stabilized, or Programmable Pulse.  Three legacy serial communications ports (two RS-232 ports and a RS-422/485 port (transmit only) are included for monitoring and status information. Optional outputs include frequency, (5, 10, 1.544 and 2.048 MHz), configurable fiber optic, configurable 24 V, additional programmable pulse and additional modulated IRIG-B outputs.

    The Model 1205B/C accepts one or two power supplies in a redundant configuration and redundant GNSS inputs.  Standard power options include an 85 to 264 Vac/100 to 350 Vdc or 22 to 67 Vdc supplies with secure terminal strip inlets and surge-withstand capability.  The surge-withstand network is designed to meet ANSI/IEEE C37.90-1 and IEC 61000-4 specifications.  Also included is a built-in lightning arrestor and rear panel ground plate to protect against secondary lightning strikes and other antenna coupled surges.

  • Model 931A Power System Analyzer
    Arbiter Systems®, Inc., Models 931A, 930A, and 929A, with state-of-the-art PowerDSA™ Digital Signal Analysis, make more measurements, more accurately, more easily, and at a lower price than ever before....
     

  •  Basic accuracy of 0.05% of reading and 0.05 phase, harmonic analysis, and full three-phase capability are standard on all three models.  The 930A and 931A also incorporate full two-way serial communication for use in power quality trend monitoring.  For complete power system analysis, the 931A also includes transducer calibration and timer features.


Send Email

Type your information and click "Send Email" to send an email to this exhibitor. To return to the previous screen without saving, click "Reset".


For questions regarding the DistribuTECH conference program please contact:
Debbi Wells Boyne, CMP
Conference Manager

DWells@pennwell.com
Direct: 918-832-9265

This site is best viewed in:
IE – 9.0, 10.0
Chrome - 14.0 and higher
Firefox - 3.0 and higher
Safari - 4.0 (Windows), 5.0 (Mac), 5.1